MKG SALES ASSOCIATES INC -- BRAKE PARTS CLEANER II -- 6850-00N084046
===================== Product Identification =====================
Product ID:BRAKE PARTS CLEANER II
MSDS Date:04/21/1995
FSC:6850
NIIN:00N084046
=== Responsible Party ===
Company Name:MKG SALES ASSOCIATES INC
Address:409 BLOOMFIELD DRIVE
City:BERLIN
State:NJ
ZIP:08009
Country:US
Info Phone Num:609-753-7111
Emergency Phone Num:800-255-3924
CAGE:JO005
=== Contractor Identification ===
Company Name:MKG SALES ASSOCIATES
Address:409 BLOOMFIELD DR UNIT 5
Box:City:BERLIN
State:NJ
ZIP:08054
Country:US
Phone:609-753-7111
CAGE:JO005
Company Name:MKG SALES ASSOCIATES INC
Address:130 MILLER RD
Box:City:MEDFORD
State:NJ
ZIP:08055
Country:US
Phone:609-953-4700
CAGE:045E5
============= Composition/Information on Ingredients =============
Ingred Name:HEXANE (CERCLA)
CAS:110-54-3
RTECS #:MN9275000
OSHA PEL:500 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB
Ingred Name:ISOPROPYL ALCOHOL; (ISOPROPANOL) (SARA 313)
CAS:67-63-0
RTECS #:NT8050000
OSHA PEL:400 PPM
ACGIH TLV:400 PPM; 500 STEL
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM; 30000 STEL
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: EXCESSIVE VAPORS
CAN CAUSE NASAL AND RESPIRATORY IRRITATION, DIZZINESS, WEAKNESS,
NAUSEA, HEADACHE, POSSIBLE UNCONSCIOUSNESS OR ASPHYXIATION. EYE
CONTACT: SLIGHT IRRITATION. SKIN CO NTACT: SLIGHT IRRITATION DUE TO
DEFATTING. INGESTION: IRRITATION. CHRONIC: EXCESSIVE INHALATION MAY
(EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HEALTH HAZARDS: RESULT IN CENTRAL NERVOUS
SYSTEM EFFECTS.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING EYE, SKIN OR
UPPER RESPIRATORY CONDITIONS.
======================= First Aid Measures =======================
First Aid:EYE CONTACT: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. IF
IRRITATED, SEEK MEDICAL ATTENTION. SKIN CONTACT: WASH WITH SOAP AND
WATER. IF IRRITATED, SEEK MEDICAL ATTENTION. INHALATION: REMOVE TO
FRESH A IR. RESUSCITATE IF NECESSARY. GET MEDICAL ATTENTION.
INGESTION: DO NOT INDUCE VOMITING. DRINK TWO LARGE GLASSES OF
WATER. GET IMMEDIATED MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EXTREMELY FLAMMABLE AS PER USA FLAME
PROJECTION TEST. DO NOT EXPOSE AEROSOLS TO TEMPERATURES ABOVE 130F
OR THE CONTAINER MAY RUPTURE.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB WITH SUITABLE MEDIUM. INCINERATE OR
LANDFILL ACCORDING TO LOCAL, STATE OR FEDERAL REGULATIONS. DO NOT
FLUSH TO SEWER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT PUNCTURE OR INCINERATE
CONTAINERS. DO NOT STORE AT TEMPERATURES ABOVE 130 F.
Other Precautions:KEEP OUT OF REACH OF CHILDREN. AVOID FOOD
CONTAMINATION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF VAPOR CONCENTRATION EXCEEDS TLV, USE NIOSH
APPROVED ORGANIC VAPOR RESPIRATOR.
Ventilation:ADEQUATE VENTILATION TO KEEP VAPOR CONCENTRATION BELOW TLV.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NONE. ANSI APPROVED EYE WASH & DELUGE SHOWER
.
Work Hygienic Practices:WASH WITH SOAP AND WATER BEFORE HANDLING FOOD.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
Vapor Pres:80-100PSIG
Spec Gravity:0.675 (H*20=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NONE
Appearance and Odor:CLEAR FORCEFUL SPRAY WITH ALIPHATIC SOLVENT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAME, WELDING ARCS, HEAT, SPARKS.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:AEROSOL CANS WHEN VENTED TO ATMOSPHERIC PRESSURE
THROUGH NORMAL USE, POSE NO DISPOSAL HAZARD. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.