PPG INDUSTRIES INC COATINGS & RESINS GROUP -- DP402LF EPOXY PRIMER CATALYST -- 8010-00F050512
===================== Product Identification ===================== Product ID:DP402LF EPOXY PRIMER CATALYST MSDS Date:04/29/1994 FSC:8010 NIIN:00F050512 === Responsible Party === Company Name:PPG INDUSTRIES INC COATINGS & RESINS GROUP Address:4325 ROSANNA DR Box:9 City:ALLISON PARK State:PA ZIP:15101-5000 Country:US Info Phone Num:412-492-5555 Emergency Phone Num:304-843-1300 CAGE:DO542 === Contractor Identification === Company Name:PPG INDUSTRIES INC. COATINGS & RESINS GP Address:4325 ROSEANNA DR PO BOX 9 Box:9 City:ALLISON PARK State:PA ZIP:15101 Phone:412-492-5555 CAGE:DO542 ============= Composition/Information on Ingredients ============= Ingred Name:ALIPHATIC AMINE ADDUCT Fraction by Wt: 5-10% Ingred Name:DIETHYLENETRIAMINE, ETHYLENEDIAMINE, N-(2-AMINOETHYL); BIS(2-AMINOETHYL)AMINE *96-2* CAS:111-40-0 RTECS #:IE1225000 Fraction by Wt: 1-2% Other REC Limits:4 MG/CUM ACGIH TLV:1 PPM (SKIN) Ingred Name:PROPYLENE GLYCOL METHYL ETHER (1-METHOXY-2-PROPANOL) PROPYLENE GLYCOL MONO METHYL ETHER *96-2* CAS:107-98-2 RTECS #:UB7700000 Fraction by Wt: 30-35% Other REC Limits:100 PPM ACGIH TLV:100 PPM Ingred Name:METHYL ETHYL KETONE, 2-BUTANONE *96-2* CAS:78-93-3 RTECS #:EL6475000 Fraction by Wt: 10-15% Other REC Limits:590 MG/CUM OSHA PEL:200 PPM ACGIH TLV:590 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:2-HEPTANONE, METHYL N-AMYL KETONE CAS:110-43-0 RTECS #:MJ5075000 Fraction by Wt: 5-10% Other REC Limits:50 PPM OSHA PEL:465 MG/CUM ACGIH TLV:233 MG/CUM Ingred Name:ISOPROPANOL (ISOPROPYL ALCOHOL), 2-PROPANOL, DIMETHYL CARBINOL (IARC CANCER REVIEW GROUP 3) *96-2* CAS:67-63-0 RTECS #:NT8050000 Fraction by Wt: 2-5% Other REC Limits:400 PPM OSHA PEL:400 PPM ACGIH TLV:400 PPM Ingred Name:BUTANOL, N-BUTYL ALCOHOL, PROPYL CARBINOL, BUTYL ALCOHOL CAS:71-36-3 RTECS #:EO1400000 Fraction by Wt: 5-10% Other REC Limits:300 MG/CUM OSHA PEL:100 PPM ACGIH TLV:C 152 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:TOLUENE (IARC CARC- GROUP 3) *96-2* CAS:108-88-3 RTECS #:XS5250000 Fraction by Wt: 2-5% Other REC Limits:375 MG/CUM OSHA PEL:100 PPM ACGIH TLV:100 PPM EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:ISOPARAFFINIC HYDROCARBONS (NAPHTHA PETROLEUM), HYDROTREATED HEAVY, NON AROMATIC HEAVY NAPHTHA) ISOPAR G CAS:64742-48-9 Fraction by Wt: 1-2% Ingred Name:OXO-HEXYL ACETATE *96-2* CAS:88230-35-7 Fraction by Wt: 2-5% Ingred Name:FILM FORMERS, RESINS, AND ADDITIVES Fraction by Wt: 20-25% ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:HARMFUL IF SWALLOWED/INHALED. MAY BE ABSORBED THROUGH THE SKIN. EYES: MAY CAUSE IRREVERSIBLE DAMAGE. SKIN: CORROSIVE, BURNS & ALLERGIC REACTIONS. INHALATION: HIGH VAPOR CONCENTRATIONS MAY CAUSE IRRITA TION OF THE RESPIRATORY SYSTEM & PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. Explanation of Carcinogenicity:NONE Effects of Overexposure:IRRITATION, EYE WATERING, HEADACHES, NAUSEA, DIZZINESS, LOSS OF COORDINATION, REDNESS, ITCHING, BURNING, VISUAL DISTURBANCES, DRYNESS, CRACKING, SWELLING. ======================= First Aid Measures ======================= First Aid:INGESTION: GIVE 1-2 GLASSES OF WATER. DON'T INDUCE VOMITING. SKIN: FLUSH W/WATER, FOLLOWED BY WATERLESS HAND CLEANER & SOAP. INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED. EYES: FLUSH W/WATER FO R 30 MINS. OBTAIN MEDICAL ATTENTION IN ALL CASES. ===================== Fire Fighting Measures ===================== Flash Point Method:PMCC Flash Point:36F Lower Limits:1.7 Extinguishing Media:CO2, DRY CHEMICAL/UNIVERSAL AQUEOUS FILM FORMING FOAM. Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. WATER SPRAY MAY BE USED TO COOL CLOSED CONTAINERS. IF WATER IS USED, FOG NOZZLES ARE PREFERABLE. WEAR SCBA. Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE FROM HEAT, ELECTRICAL EQUIPMENT & OTHER IGNITION SOURCES. DON'T APPLY TO HOT SURFACES. (SEE SUPP) ================== Accidental Release Measures ================== Spill Release Procedures:USE MAXIMUM VENTILATION. ONLY PERSONNEL EQUIPPED W/PROPER RESPIRATORY & SKIN/EYE PROTECTION, PERMITTED. REMOVE IGNITION SOURCES. TAKE UP W/SAWDUST, VERMICULITE/OTHER ABSORBENT MATERIAL & PLACE INTO CO NTAINERS FOR DISPOSAL. ====================== Handling and Storage ====================== Handling and Storage Precautions:GROUND CONTAINER WHEN POURING. AVOID FREE FALL OF LIQUIDS IN EXCESS OF A FEW INCHES. DON'T STORE >120F. Other Precautions:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING & INHALING THE CONTENTS CAN BE HARMFUL/FATAL. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH/MSHA APPROVED AIR PURIFYING/AIR SUPPLIED RESPIRATORS. Ventilation:GENERAL DILUTION/LOCAL EXHAUST VENTILATION. Protective Gloves:BUTYL, NEOPRENE/NITRILE RUBBER Eye Protection:CHEMICAL SPLASH GOGGLES/FULL FACE SHIELD Other Protective Equipment:IMPERMEABLE CLOTHING Supplemental Safety and Health UNUSUAL FIRE CONT'D: CLOSED CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. TOXIC GASES MAY FORM WHEN PRODUCT IS CONTACTED BY FLAME/HOT SURFACES. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:132-8-401F Vapor Pres:24.9 Vapor Density:>1 Spec Gravity:0.93 Evaporation Rate & Reference:(BU OAC =100): 218 Solubility in Water:42.8 Appearance and Odor:VISCOUS LIQUID W/CHARACTERISTIC ODOR OF THE SOLVENTS LISTED. Percent Volatiles by Volume:72.48 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG ALKALIES, STRONG MINERAL ACIDS/STRONG OXIDIZING AGENTS. Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES, ELECTRICAL EQUIPMENT & OTHER IGNITION SOURCES. TEMP >120F. Hazardous Decomposition Products:HEATED, WELDING, BRAZING/FLAME CUTTING: CO, OXIDES OF NITROGEN. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS. EMPTY CONTAINERS SHOULD BE RECYCLED/DISPOSED OF THROUGH AN APPROVED WASTE MANAGEMENT FACILITY. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.